Particle Image Analyzers
Inquiry NowProduct Description
M-Kube Enterprise LLC provides Particle Image Analyzers for manufacturers, quality control teams, research organizations, universities, testing facilities, and industrial users across the United States. Designed for applications where particle size alone does not provide the complete picture, these systems combine digital imaging with advanced particle image analysis to evaluate particle size, shape, morphology, and distribution.
Unlike measurement techniques that primarily calculate particle size distribution from an indirect signal, a particle image analysis system captures and evaluates images of individual particles. This allows users to visually inspect the particles being measured while generating quantitative information about their dimensions and morphological characteristics.
This additional visual information can be particularly valuable when particle shape, agglomeration, circularity, sphericity, aspect ratio, or unusual particle geometry can influence material behavior, processing, or final-product performance.
M-Kube offers static microscopy-based systems as well as wet and dry dynamic image analyzer configurations. The available range supports applications involving dry powders, flowing particulate materials, suspensions, slurries, minerals, pharmaceuticals, ceramics, pigments, food powders, battery materials, chemicals, and other industrial materials.
Static vs. Dynamic Particle Image Analysis
The appropriate analyzer depends largely on how the sample needs to be prepared and how particles should be observed during measurement.
M-Kube’s range includes static microscope-based analysis, dynamic wet analysis, dynamic dry analysis, and automated microscopy configurations.
Static Image Analysis for Detailed Particle Morphology
Static image analysis is useful when users need close visual examination of individual particles together with detailed particle-size and morphology information.
A prepared sample is viewed through an optical microscope, captured using a digital imaging system, and processed using particle-recognition and image-analysis software.
This approach can support:
- Detailed particle morphology studies
- Particle size distribution analysis
- Individual particle inspection
- Aspect-ratio measurements
- Sphericity and roundness evaluation
- Particle counting
- Investigation of agglomerates or unusual particle shapes
- Research and quality-control applications
Model 99E is M-Kube’s dedicated static image particle-size analyzer and provides a published measurement range of 1–6000 μm.
Dynamic Wet Image Analysis for Suspensions and Slurries
For materials that need to remain dispersed in liquid during measurement, a dynamic wet system continuously circulates and images particles while they move through the measurement area.
Model 100D combines real-time image acquisition with an integrated wet dispersion arrangement. Mechanical circulation and ultrasonic dispersion help maintain sample dispersion during analysis.
The system has a published measurement range of 5–3000 μm and can analyze more than 100,000 particles per minute, with image acquisition up to 120 frames per second.
Typical applications include suspensions, slurries, pigments, coatings, minerals, ceramics, pharmaceuticals, lithium battery materials, abrasives, metal powders, cement, and other liquid-dispersed particulate materials.
Dynamic Dry Image Analysis for Powders
A dynamic image analyzer for dry materials allows particles to be evaluated while moving through the measurement system rather than being manually positioned on a microscope slide.
Model 300D is designed for dry powders and flowing particulate materials. Particles are continuously introduced into the measurement system, imaged in real time, and statistically analyzed.
The system provides a published measurement range of 10–10,000 μm and supports analysis rates of more than 100,000 particles per minute.
Dynamic dry analysis can be considered for materials such as:
- Salt and sugar
- Plastics
- Catalysts
- Abrasives
- Carbon materials
- Sand
- Coal
- Coffee
- Refractories
- Food powders
- Fertilizers
- Pharmaceuticals
- Metal powders
- Cement
- Minerals and ores
- Ceramics
- Glass
This approach can be particularly useful when users want particle-size and morphology information from a larger population of moving dry particles.
Performance and Image Analysis Features
Depending on the selected model and configuration, M-Kube Particle Image Analyzers can provide:
- Advanced particle image analysis for particle size and morphology characterization
- High-resolution digital image acquisition
- Automated particle recognition and segmentation
- Particle segmentation speed of less than 1 second on Model 99E
- Greater than 98% segmentation success rate on Model 99E
- Automatic adaptive binarization
- Automatic noise removal
- Automatic removal of particles with incomplete boundaries
- Automatic filling of hollow particle areas
- Automatic particle-edge smoothing
- Automatic separation of adhered particles
- Automatic acquisition of particle size and shape parameters
- Seamless image stitching
- Individual particle analysis
- D10, D50, D90, and other characteristic particle-size parameters
- Frequency and cumulative distribution analysis
- Particle-size distribution by number, volume, and area
- Aspect ratio
- Bulkiness
- Sphericity
- Circularity and roundness
- Surface-area analysis
- Specific surface-area parameters
- Direct particle counting
- Particle-image storage
- Flexible reporting and task-management functions
- Automated image-processing functions
- Wet and dry dispersion options depending on model
- High-throughput dynamic particle analysis on selected systems
Selecting the Right Particle Image Analyzer
The appropriate system depends on the sample type, particle-size range, required morphology information, preferred dispersion method, testing volume, and desired level of automation.
| Requirement | Recommended Configuration |
| Detailed microscopic particle inspection | Model 99E static image analysis |
| Particle morphology and individual particle visualization | Static image analysis |
| Suspensions, slurries, or wet samples | Model 100D dynamic wet analysis |
| Dry flowing powders | Model 300D dynamic dry analysis |
| Automated microscope-based analysis | Model 219 |
| High-throughput dry particle characterization | Model 300D |
| High-throughput wet particle characterization | Model 100D |
| Broad particle range with automated microscopy | Model 219 |
| Research requiring size and morphology information | Static or dynamic configuration based on sample type |
Particle Image Analyzer Models Available from M-Kube
M-Kube offers multiple particle image analysis system configurations for different sample types and measurement requirements.
| Model | Analysis Type | Measurement Range | Primary Application |
| Model 99E | Static Image Analysis | 1–6000 μm | Microscopy, particle size & detailed morphology |
| Model 100D | Dynamic Wet Image Analysis | 5–3000 μm | Suspensions, slurries & wet samples |
| Model 219 | Automated Microscope / Static & Dynamic | 5–10,000 μm | Automated particle characterization |
| Model 300D | Dynamic Dry Image Analysis | 10–10,000 μm | Dry powders & flowing particulate materials |
Model 300D – Dynamic Dry Particle Image Analyzer
Model 300D is designed for dynamic analysis of dry, flowing powders and particulate materials.
Particles are continuously introduced into the measurement system, imaged in real time, and statistically analyzed. The system incorporates a 5-megapixel high-speed industrial camera and a high-definition telecentric lens.
Key Features
- Dynamic dry particle image analysis
- 10–10,000 μm measurement range
- Customizable measurement range
- High-speed industrial camera
- Telecentric optical system
- More than 100,000 particles/minute analysis capability
- Electromagnetic vibration feeding
- Electromagnetic and ultrasonic dispersion
- Particle size and morphology analysis
- D10 / D50 / D90
- Aspect ratio and distribution
- Roundness and distribution
- Particle count
- Particle image analysis
- Offline testing
- Online testing capability with suitable sampling configuration
- Excel/PDF reporting
Model 100D – Dynamic Wet Particle Image Analyzer
Model 100D is designed for wet particle and suspension analysis, combining real-time image acquisition with an integrated wet dispersion system.
The system uses a circulation-based wet dispersion arrangement together with ultrasonic dispersion to improve sample dispersion. It can analyze more than 100,000 particles per minute with image acquisition up to 120 frames per second.
Key Features
- Dynamic wet particle image analysis
- 5–3000 μm measurement range
- Customizable range
- Automatic wet dispersion
- Integrated circulation system
- Dual ultrasonic dispersion
- High-speed imaging up to 120 frames/s
- High-definition telecentric lens
- Particle size and morphology analysis
- Particle count
- D10 / D50 / D90
- Aspect ratio
- Circularity
- Particle images
- Real-time concentration and particle count
- Batch image processing
- Automated particle-processing tools
Model 219 – Automated Microscope Particle Size Analyzer
Model 219 combines automated microscopy and image analysis for particle-size and morphology characterization.
Depending on configuration, the system can support static and dynamic measurement modes with automated platform movement and focusing. A 5-megapixel high-speed industrial camera, maximum magnification of 2000×, and automated measurement controls support more automated particle characterization.
Key Features
- 5–10,000 μm particle-size range
- Static and dynamic measurement capability
- Automated image acquisition
- High-speed industrial camera
- Up to 2000× magnification
- Automatic platform movement
- Electric focusing
- Dry and wet dispersion options
- D10 / D50 / D90
- Particle count
- Aspect ratio
- Roundness
- Particle images
- Intelligent operating mode
- Automated test sequence
- Excel/PDF reporting
Model 99E – Static Image Particle Size Analyzer
Model 99E is a microscope-based static image analyzer designed for particle-size distribution and morphology analysis.
It combines optical microscopy, high-resolution image acquisition, and image-processing software to characterize individual particles and particle populations. The system provides a published measurement range of 1–6000 μm, image resolution up to 2048 × 1536 pixels, and optical magnification from 4× to 5000×, depending on configuration.
Key Features
- 1–6000 μm measurement range
- High-resolution CMOS imaging
- Optical microscope-based analysis
- 4×–5000× magnification configuration
- Image stitching
- Automatic particle segmentation
- Adaptive image binarization
- Automatic removal of incomplete boundary particles
- Particle-size distribution
- D10 / D50 / D90
- Particle count
- Aspect ratio
- Sphericity
- Circularity / roundness
- Individual particle analysis
- Particle-image storage
- Manual and automated analysis functions
Typical Technical Specifications – Model 99E
| Specification | Model 99E |
| Instrument Type | Static Image Particle Size Analyzer |
| Measurement Range | 1–6000 μm |
| Maximum Image Resolution | 2048 × 1536 pixels |
| Pixel Size | 3.2 × 3.2 μm |
| Segmentation Speed | <1 second |
| Segmentation Success Rate | >98% |
| Connection Port | USB 3.0 |
| Eyepiece | 10X wide-field eyepiece |
| Objective Lenses | 4X, 10X, 40X, 100X oil long-distance chromatic-aberration-correcting plan objectives |
| Magnification | 4–5000X |
| Bottom Light Source | Transmitted light; halogen or LED, adjustable brightness |
| Top Light Source | Metallographic incident light with polarizer |
| Mechanical Stage | Manual 3D mechanical stage |
| Stage Dimensions | 185 × 140 mm |
| Stage Movement Range | 50 × 75 mm |
| Fine Adjustment Increment | 2 μm |
| Image Acquisition | Particle morphology images |
| Image Formats | JPG and BMP |
| Image Stitching | Seamless stitching of multiple fields of view |
| Automatic Processing | 12 automatic image-processing tools |
| Particle Size Parameters | D10, D50, D90, D100 and other characteristic parameters |
| Distribution Analysis | Frequency and cumulative distribution |
| Distribution Basis | Number, volume and area |
| Shape Parameters | Aspect ratio, bulkiness, sphericity, surface area, specific surface area and other morphology parameters |
| Particle Counting | Direct particle count |
| Data Management | Task management system |
| Report Images | Color or black-and-white particle thumbnails |
| Calibration | Calibration using a standard micrometer |
The specifications above are based on the supplied Model 99E reference information. Final configuration, optics, software functions, and accessories should be confirmed according to the selected instrument configuration and application requirements.
Particle Image Analyzers Comparison
| Feature | Model 99E | Model 100D | Model 219 | Model 300D |
| Analysis Mode | Static | Dynamic wet | Static / Dynamic* | Dynamic dry |
| Measurement Range | 1–6000 μm | 5–3000 μm | 5–10,000 μm | 10–10,000 μm |
| Sample Type | Dry/static samples | Wet/suspension | Dry or wet* | Dry powders |
| Image Analysis | ✓ | ✓ | ✓ | ✓ |
| Particle Morphology | ✓ | ✓ | ✓ | ✓ |
| D10 / D50 / D90 | ✓ | ✓ | ✓ | ✓ |
| Particle Count | ✓ | ✓ | ✓ | ✓ |
| Aspect Ratio | ✓ | ✓ | ✓ | ✓ |
| Circularity / Roundness | ✓ | ✓ | ✓ | ✓ |
| Dynamic Measurement | — | ✓ | ✓* | ✓ |
| Automated Operation | ✓ | ✓ | ✓ | ✓ |
| High-Throughput Analysis | — | ✓ | ✓* | ✓ |
| Best Suited To | Microscopy & detailed morphology | Suspensions & wet samples | Automated microscopy | Dry flowing powders |
Particle Image Analysis Applications
A particle morphology analyzer can provide additional information beyond particle-size distribution when particle shape and structure are important to product development, process control, or material performance.
Pharmaceutical & Healthcare Materials
Evaluate active pharmaceutical ingredients, excipients, pharmaceutical powders, granules, and crystalline materials where particle size, shape, and morphology can be important to development and quality-control workflows.
Battery & Advanced Materials
Characterize battery powders, graphite, active materials, conductive materials, ceramic powders, and metal powders using image-based particle-size and morphology information.
Ceramics & Refractory Materials
Analyze ceramic powders, refractory raw materials, alumina, silica, mineral powders, and other particulate materials used in development, manufacturing, and process quality control.
Paints, Coatings, Inks & Pigments
Evaluate pigments, fillers, coating powders, ink materials, and functional additives where particle size, shape, or agglomeration may need to be investigated.
Chemicals & Catalysts
Support characterization of catalysts, chemical powders, fillers, pigments, and functional materials used in chemical manufacturing and product development.
Mining, Minerals & Geological Materials
Analyze mineral particles, ores, geological samples, aggregates, fines, and slurries for particle-size and morphology characterization.
Food & Agricultural Materials
Evaluate flour, sugar, salt, food powders, food additives, and agricultural powders where particle size and shape can influence processing and product consistency.
Abrasives, Metals & Powder Processing
Characterize abrasive grains, carbides, ceramics, metal powders, and industrial powders used in manufacturing and advanced-material applications.
Why Customers Work with M-Kube Enterprise
M-Kube Enterprise works with manufacturers, quality teams, research organizations, universities, testing facilities, and industrial customers looking for Particle Image Analyzer Suppliers that can help identify an appropriate system based on the actual sample and analysis requirements.
Available solutions and support include:
- Static, dynamic wet, and dynamic dry particle image analysis configurations
- Particle size and particle shape analysis within one system
- High-resolution microscopy and digital image acquisition
- Automated particle segmentation and image-processing functions
- Image stitching for analysis of larger particle populations
- D10, D50, D90, and D100 particle-size parameters on applicable configurations
- Quantitative morphology analysis including sphericity, aspect ratio, and roundness
- Direct particle visualization and counting
- Solutions for pharmaceutical, ceramic, chemical, mineral, food, pigment, cement, catalyst, battery, and powder applications
- Systems for research, manufacturing, product development, quality control, and university applications
- Technical assistance for selecting static or dynamic image-analysis configurations
- Application-specific instrument selection support
- Competitive particle image analyzer price based on instrument configuration, optics, software, accessories, and application requirements
M-Kube analytical equipment is manufactured in ISO-certified facilities and tested in accordance with relevant ASTM standards. This provides U.S. customers with a recognized quality and testing framework when evaluating analytical equipment for manufacturing, research, development, testing, and quality-control applications.
Request a Quote for a Particle Image Analyzer
If you are comparing a particle image analyzer, dynamic image analyzer, particle morphology analyzer, or complete particle image analysis system, Camsizer particle size analysis M-Kube Enterprise can help identify a suitable configuration based on your sample and measurement requirements.
For a more useful recommendation and quotation, share your sample material, approximate particle-size range, whether the sample will be analyzed dry or wet, the morphology parameters of interest, and any automation or reporting requirements.
Contact M-Kube Enterprise – U.S. Sales & Product Information
Phone: +1-732-808-1999
Email: info@mkubeenterprise.com
Contact M-Kube Enterprise for particle image analyzer price, current configuration information, technical specifications, and application guidance.
Product FAQ's
What is a Particle Image Analyzer?
A Particle Image Analyzer captures images of individual particles and uses image-processing software to determine particle size, particle-size distribution, and morphological characteristics.
What is particle image analysis?
Particle image analysis uses digital images of particles to measure their dimensions and shape. Unlike methods that infer particle size from another physical signal, image analysis allows users to directly view the particles being evaluated.
What is the difference between particle image analysis and laser particle-size analysis?
Laser particle-size analysis determines particle-size distribution from the interaction of particles with laser light, while particle image analysis directly captures particle images and measures their dimensions and shape.
Can a Particle Image Analyzer measure particle shape?
Yes. Depending on the model and software, measured parameters can include aspect ratio, circularity, roundness, sphericity, and other morphology characteristics.
Can image analyzers measure both dry and wet samples?
Yes. M-Kube’s range includes dedicated dynamic dry and dynamic wet systems as well as microscope-based configurations.
What is the smallest particle size that can be measured?
The measurement range depends on the model and optical configuration. Model 99E has a published lower measurement limit of approximately 1 μm, while other models are optimized for larger particles and higher-throughput dynamic analysis.
Can I see the actual particles being measured?
Yes. This is one of the main advantages of particle image analysis. Particle images can be captured, displayed, stored, and incorporated into analysis and reporting workflows.
Which analyzer should I choose for dry powder?
For high-throughput dynamic dry-powder characterization, Model 300D is specifically designed for this application. For static microscope-based characterization, Model 99E or an appropriate Model 219 configuration may be considered.
Which analyzer should I choose for a suspension?
Model 100D is specifically designed for dynamic wet particle image analysis and incorporates an automated wet dispersion system.
What affects particle image analyzer price?
Particle image analyzer price depends on the selected model, measurement range, optical configuration, imaging system, software functions, automation requirements, dispersion system, and accessories.
M-Kube Enterprise can review the sample and testing requirements and provide configuration and pricing information for the appropriate system.